Horizontal vs Vertical Illuminance: When Ev Matters More

Horizontal vs Vertical Illuminance: When Ev Matters More

Horizontal vs vertical illuminance illustration (Eh vs Ev)
Eh vs Ev-surface brightness vs readability for broadcast and video.

Many sports lighting projects pass average lux requirements but still look visually flat-especially on camera. The missing piece is usually vertical illuminance (Ev) and how it’s defined, simulated, and measured.

Answer: Horizontal illuminance (Eh) tells you how bright the playing surface is, but vertical illuminance (Ev) determines how well players, faces, and objects are lit from real viewing directions-so it often drives broadcast and recognition quality.
If your project includes competition, video review, or TV coverage, you should define Ev height + directions early and align the commissioning method to the calculation report.
  • Key takeaway #1: Eh builds surface brightness; Ev builds readability of people/objects and camera image quality.
  • Key takeaway #2: Ev is direction-dependent-define the viewing/camera directions before simulation and before site tests.
  • Key takeaway #3: Improve Ev with optics + aiming strategy first, not by simply increasing power (which may worsen glare/spill).

When this applies

Use this guide when your venue is designed for competition or broadcast, or when stakeholders complain about “bright ground but dark players.” It’s also useful for retrofit projects where pole locations are fixed and you need to optimize the light direction.

Typical scenarios

  • Broadcast or TV coverage: Ev often becomes as important as Eh.
  • Training fields with video review: basic Ev targets prevent poor facial recognition and flat images.
  • Multi-sport complexes: different sports have different Ev sensitivity (ball in air, camera angles).
  • Fixed-pole retrofits: you must “steer” light with optics + aiming to build Ev without increasing glare.

Key requirements / metrics

This table explains the difference between Eh and Ev and why both must be designed and verified together.

Metric Definition When it matters most Design implication
Horizontal illuminance
Eh
Illuminance on the playing surface (typically measured on a horizontal plane). General play visibility, surface brightness, baseline compliance. Driven by total lumens delivered to the field and distribution uniformity.
Vertical illuminance
Ev
Illuminance on a vertical plane (faces/players/objects) from defined viewing directions. Broadcast image quality, facial recognition, coaching video, ball tracking in air. Requires delivering light from useful directions—not only “down to the ground.”
Vertical-to-horizontal balance
Ev/Eh
A practical indicator of “bright ground vs bright faces” balance. Projects that look compliant on paper but feel visually flat in reality. Often improved by optics + aiming strategy (not just adding power).

Definitions

Eh describes how much light reaches the playing surface. Ev describes how much light reaches vertical subjects (players, faces, ball) from a defined direction. That “direction” is the key: Ev is viewpoint-dependent—so you must define measurement directions (camera positions, stands, or cardinal directions).

If Ev is required, document height and direction in both simulation and commissioning. Otherwise you may measure a different “Ev” than what you designed.

Typical target ranges

Exact numeric Ev targets depend on sport, class, and broadcast requirements. A practical approach is:

  • Non-broadcast training: prioritize Eh and basic uniformity; define a simple Ev minimum only if video/recognition matters.
  • Competition: define Ev for main stand / typical viewing directions to avoid “dark faces.”
  • Broadcast: define Ev for camera directions and include flicker metrics as well.

When no Ev target is stated in the tender, define an Ev acceptance method (height + directions) early to reduce disputes.

Want a tender-ready pack based on your real pole layout?
Get a calculation report + IES/LDT + spec clauses (with aiming & sign-off checklist).

Step-by-step workflow

Engineering workflow diagram for vertical illuminance planning and verification
Engineering diagram: Define Ev height/directions → simulate → aim → verify on site.

The core idea: Eh makes the field bright; Ev makes people and objects readable. The project succeeds when both are aligned to the real viewing directions.

Inputs to collect (must-have)

  • Use case: training / competition / broadcast; is video quality a requirement?
  • Viewing directions: main stands, typical coach positions, and any camera locations.
  • Pole geometry: height, positions, maximum tilt, and restricted aiming directions.
  • Constraints: glare/spill limits, neighbor viewpoints, and curfew rules.

Design decisions (key points)

  1. Define Ev directions before simulation. “Ev” without a direction becomes meaningless at sign-off.
  2. Deliver light from useful angles. Optics + aiming should push light into the viewing direction while controlling high-angle glare.
  3. Balance more fixtures vs brighter fixtures. Very bright sources can improve Eh but create glare and poor modelling.
  4. Lock the Ev/Eh acceptance method. Define how it will be measured and reported, not only what the numbers are.

Verification & sign-off (how to accept)

  • Report tables: include Eh grid and Ev results with stated height and direction(s).
  • Commissioning plan: align measurement points and directions with the report; record conditions and angles.
  • Aiming record: final aiming angles must be captured-small changes shift Ev significantly.

Common mistakes

  • Only designing for Eh: the field looks bright but players look dark (especially on camera).
  • Ev direction not defined: you simulate one direction and measure another-leading to disputes.
  • Measuring Ev incorrectly: wrong height, wrong facing direction, or inconsistent method across points.
  • Fixing Ev by “more power”: can increase glare and spill; use optics + aiming first.
  • No coordination with cameras: broadcast requirements must be confirmed before design freeze.

Checklist / Template download

Ev Planning Worksheet (CSV)

Define Ev needs early: directions, height, and acceptance method.

Camera / View Direction Checklist (CSV)

Lock critical viewing directions before design freeze.

Ev + Eh Measurement Record (CSV)

A commissioning sheet to measure Ev consistently on site.

Ev Specification Clause (TXT)

Copy-paste language to include Ev in a tender-ready specification.

Request the full pack

On your website, connect this form to your CRM / email automation. This is a preview layout for your team.

Privacy: we use your details only for document delivery and technical follow-up about this request.

FAQ

What is the simplest way to explain vertical illuminance (Ev) to a buyer?

Horizontal illuminance (Eh) tells you how bright the field surface is. Vertical illuminance (Ev) tells you how well faces, players, and objects are lit from viewing directions—so it often drives visibility and broadcast quality.

Do I need Ev for non-broadcast training fields?

Often not as a primary requirement. But if the field is used for coaching, video review, or community events, defining a basic Ev target can prevent the “bright ground, dark faces” problem.

How is Ev measured on site?

Ev is measured with the meter oriented vertically (facing a defined direction). A good plan defines measurement height, direction(s), and the grid before commissioning.

Why can a design pass average lux but still look ‘flat’ on camera?

Because good camera images depend on light coming from useful directions. High Eh with weak Ev can produce poor modelling, low facial recognition, and inconsistent exposure.

How do I improve Ev without increasing glare?

Use more controlled optics and aiming strategies to deliver light from useful angles while limiting high-angle spill. Avoid making a few luminaires excessively bright.

Get a Quote

Tell us about your project

For the fastest pricing, include model, quantity, application, and installation height.

Trust & Privacy

We respect your privacy. Your information will only be used to respond to your inquiry.

Upload project spec, layout, or drawing.